- Display 15 Products per page
Filters Sort results
Reset Apply
1K4X OPEN-CLOSE with Center Return Key Switch, Mortise Cylinder, Non-Tamperproof, Rosite Enclosure, H=4-1/4, W=4-1/4"", D=2-1/2"" | ||
3BLM-BC OPEN-CLOSE-STOP Push Button with Best Cylinder or Equivalent Lockout, Metal Enclosure, Buttons aligned vertically, H=7, W=2-3/4"", D=3-1/2"" | ||
3BFLX-BC OPEN-CLOSE-STOP Push Button with Best Cylinder or Equivalent Lockout, Metal Enclosure, Buttons aligned in a triangular pattern, Faceplate: H=6"", W=4-3/4"", D=2-7/8"", Back Box: H=3-3/4"", W=3-3/4"" | ||
1KX OPEN-CLOSE with Center Return Key Switch, Mortise Cylinder, Tamperproof, H=4-3/8"", W=4-1/8"", D=2-5/8"" | ||
1BX Metal Enclosure, H=4-3/8"" W=4-1/8"" D-2-5/8"" | ||
PBTL-3 OPEN-CLOSE-STOP Push Button with Lockout, Metal Enclosure, Buttons aligned vertically, H=7"" W=2-3/4"" D=3-1/2"" | ||
MLC-K36 Monitored Light Curtain, Height: 36 Inches; Sensing Distance: 32 Feet; Waterproof Housing (IP67) | ||
FOS PHOTOCELL Exterior Through-Beam Photocell, Sensing Distance 45 Feet, UL325/2010 Recognized Component, Comes with Sender, Receiver and Brackets, NEMA 4 & 4X | ||
1KFX-SLF OPEN-CLOSE with Center Return Key Switch, S Type Large Format Cylinder, Flush Mount, Tamperproof, Faceplate: H=6", W=4-3/4", D=2-7/8", Back Box: H=3-3/4", W=3-3/4" | ||
1KFX-BC OPEN-CLOSE with Center Return Key Switch, Best Cylinder or Equivalent, Flush Mount, Tamperproof, Faceplate: H=6"", W=4-3/4"", D=2-7/8"", Back Box: H=3-3/4"", W=3-3/4"" | ||
1MHD Momentary Contact, Metal Enclosure, Double Pole Contacts, Red Push Button, H=3-1/2"", W=3"", D=3"" | ||
HBFX-SLF OPEN-CLOSE with Center Return Key Switch, S Type Large Format Cylinder, Stainless Steel Faceplate, Faceplate: H= 4-1/2", W=2-3/4", Back Box: H=4", W=2", D=2" | ||
AB 60-2828 Exterior Long Distance Through-Beam Photocell, Voltage: 12-24 VAC/DC, Sensing Distance = 200 Feet, Comes with Emitter, Receiver, Mounting Brackets, Protective Hoods, Weatherproof Caps and 6 Feet of Cable, NEMA 4, 4X, IP67. UL325/2018 Certified for monitoring normally closed circuit and also for dry contact CSA Certified, CE Certified. | ||
1KX-BC OPEN-CLOSE with Center Return Key Switch, Best Cylinder or Equivalent, Tamperproof, H=4-3/8"", W=4-1/8"", D=2-5/8"" | ||
2BXC OPEN-CLOSE Push Button with Protective Cover for Wet Locations, Metal Enclosure H=4-1/2"", W=2-3/4"", D=2-3/4"" | ||
3BXLT OPEN-CLOSE-STOP Push Button with Lockout, Non-Metallic Enclosure, Double Pole Contacts, Buttons aligned vertically, H=7"" W= 2-3/4"" D=2-3/4"" | ||
HBFSX-CC OPEN-CLOSE with Center Return Key Switch with Stop Button, Changeable Core Cylinder, Stainless Steel Faceplate, Faceplate: H= 4-1/2", W=2-3/4", Back Box: H=4", W=2", D=2" | ||
OAM-Explorer The OAM-EXPLORER uses a large microwave detection area for activation, and infrared technology for safety around the threshold. The sensor can control external devices such as warning lights or alarms in order to warn vehicles and pedestrians on the opposite side of the door. Configuration and fine-tuning can be done with via a smart phone app. Voltage: 12-24VAC/DC, NEMA 4, Mounting Height: 6'7" - 19'8". | ||
1KFSX OPEN-CLOSE with Center Return Key Switch with Stop Button, Mortise Cylinder, Flush Mount, Tamperproof, Faceplate: H=6"", W=4-3/4"", D=2-7/8"", Back Box: 3-3/4"", W=3-3/4"" | ||
RLC-K36 Non-Monitored Light Curtain, Height: 36 Inches; Sensing Distance: 32 Feet; Waterproof Housing (IP67) | ||
3BX OPEN-CLOSE-STOP Push Button, Metal Enclosure, Buttons aligned in a triangular pattern, H=4-3/8"" W=4-1/8"" D=2-5/8"" | ||
HBFSX-BC OPEN-CLOSE with Center Return Key Switch with Stop Button, Best Core Cylinder or Equivalent, Stainless Steel Faceplate, Faceplate: H= 4-1/2", W=2-3/4", Back Box: H=4", W=2", D=2" | ||
1KFX-CC OPEN-CLOSE with Center Return Key Switch, Changeable Cylinder, Flush Mount, Tamperproof, Faceplate: H=6", W=4-3/4", D=2-7/8", Back Box: H=3-3/4", W=3-3/4" | ||
CPS-UN4 Exterior UL325/2010 Photocell, Back Compatible, Through-Beam, Works with LiftMaster Operators Only, Replaces the CPS-LN4 | ||
3BFLX OPEN-CLOSE-STOP Push Button with Lockout, Metal Enclosure, Buttons aligned in a triangular pattern, Faceplate: H=6"", W=4-3/4"", D=2-7/8"", Back Box: H=3-3/4"", W=3-3/4"" | ||
3BXT OPEN-CLOSE-STOP Push Button, Non-Metallic Enclosure, Double Pole Contacts, Buttons aligned vertically, H=5-3/4"" W=2-3/4"" D=2-1/2"" | ||
IS40 Motion (Microwave) and Presence (Infrared) Detector with Unidirectional or Bidirectional, 6 Modes of Detection Filtering with Pedestrian and Parallel Traffic Rejection, 9 Unique Infrared Patterns, Adjustable Infrared Immunity Models, Waterproof (NEMA 4), Voltage: 12-24VAC/DC, Available Mounting Height Options: Standard 8' - 16'; XL 6-1/2' - 11'; **NOTE: Optional Programming Remote Available - See P/N REMOTE; Optional Heavy Duty Bracket - See P/N HDB
| ||
HBFX-BC OPEN-CLOSE with Center Return Key Switch, Best Cylinder or Equivalent, Stainless Steel Faceplate, Faceplate: H= 4-1/2"", W=2-3/4"", Back Box: H=4"", W=2"", D=2"" | ||
1BXT Non-Metallic Enclosure, Double Pole Contacts, H=3-1/4"" W=2-3/4"" D=2-1/2"" | ||
PT724AE 365 Day Timer, 24 Hour Timer that Provides Many Latching and/or Momentary Operations, Events may be set for Single or Multiple Operations on a Daily and/or Weekly Schedule, Individually Selected Holiday Exceptions can be Programmed to Override Regularly Scheduled Events, Comes Mounted in Weatherproof Enclosure, Voltage: 12-24VAC/DC | ||
1BXC One Button with Protective Cover for Wet Locations, Metal Enclosure, H=4-1/2"", W=2-3/4"", D=2-3/4"" | ||
FALCON Motion Detector for Industrial Doors, Gates and Warning Indication, Unidirectional and Bidirectional, 6 Modes of Detection Filtering for Pedestrian and Parallel Traffic, Waterproof (NEMA 4), Voltage: 12-24VAC/DC, Available Mounting Height Options: Standard 11-1/2' - 23'; XL 6-1/2' - 11'; **NOTE: Optional Programming Remote Available - See P/N REMOTE; Optional Heavy Duty Bracket - See P/N HDB | ||
3B4X OPEN-CLOSE-STOP Push Button, Rosite Enclosure, Buttons aligned in a triangular pattern, H=4-1/4"", W=4-1/4"", D=2-1/2"" | ||
1KXL ON-OFF Two Position Key Switch, Mortise Cylinder, H=4-3/8"", W=4-1/8"", D=2-5/8"" | ||
3BXC OPEN-CLOSE-STOP Push Button with Protective Cover for Wet Locations, Metal Enclosure, H=4-1/2"", W=2-3/4"", D=2-3/4"" | ||
1KFX OPEN-CLOSE with Center Return Key Switch, Mortise Cylinder, Flush Mount, Tamperproof, Faceplate: H=6"", W=4-3/4"", D=2-7/8"", Back Box: H=3-3/4"", W=3-3/4"" | ||
2BX OPEN-CLOSE Push Button, Metal Enclosure, Buttons aligned vertically, H=4-3/8"" W= 4-1/8"" D=2-5/8"" | ||
OMRON E3JM Exterior Through-Beam Photocell, Voltage: 24-240VAC/12-240VDC, Sensing Distance=32 Feet, Comes with Emitter, Receiver and Brackets, 1P 66 Rated Watertight and Dust-tight, UL Listed | ||
1KXL-CC ON-OFF Two Position Key Switch, Changeable Cylinder, H=4-3/8", W=4-1/8"", D=2-5/8" | ||
1KXL-O HOLD OPEN-CLOSE Two Position Key Switch, Mortise Cylinder, H=4-3/8"", W=4-1/8"", D=2-5/8"" | ||
60-2728 Exterior Retro-reflective Photocell, Voltage: 12VDC/24VAC/DC, Sensing Distance=30 Feet, Comes with Bracket and Reflector, NEMA 3, 4, 4X, 6P & 13 | ||
3BLM OPEN-CLOSE-STOP Push Button with Mortise Lockout, Metal Enclosure, Buttons aligned vertically, H=7"", W=2-3/4"", D=3-1/2"" | ||
RLC-K72 Non-Monitored Light Curtain, Height: 72 Inches; Sensing Distance: 32 Feet; Waterproof Housing (IP67) | ||
1KXL-BC ON-OFF Two Position Key Switch, Best Cylinder or Equivalent, H=4-3/8"", W=4-1/8"", D=2-5/8"" | ||
1KFSX-BC OPEN-CLOSE with Center Return Key Switch with Stop Button, Best Cylinder or Equivalent, Flush Mount, Tamperproof, Faceplate: H=6"", W=4-3/4"", D=2-7/8"", Back Box: 3-3/4"", W=3-3/4"" | ||
3B4XL OPEN-CLOSE-STOP Push Button with Lockout, Rosite Enclosure, Buttons aligned in a triangular pattern, H=4-1/4"", W=4-1/4"", D=2-1/2"" |